| Technical
Specifications for Apron Bridge |
| Service Life
Expectancy |
20 years |
| Permitted
Loading |
| Ground Load |
200 kg/m² |
| Roof Load |
15 kg/m² |
|
| Cabin
Rotation |
Counter Clockwise 90°
Clockwise 30º |
| Cabin
Floor Heights |
Max 5.00 m ; 9.00 m (A380)
Min 2.00 m ; 3.80 m (A380) |
| Fixed
Pixot Height [Rotunda] |
4.5 m ; 7.5 m (A380) |
| Elevation
Speed |
Variable from 0 to 1.2m/min |
| Extension
Speed |
Variable from 0 to 16.0 m/min |
| Number
of Sections |
2 Tunnels / 3 Tunnels |
| MAB-2T
(m) |
| Extended/ |
15.0/11.0 |
19.0/13.0 |
23.0/15.0 |
27.0/17.0 |
31.0/19.0 |
35.0/21.0 |
39.0/24.0 |
| Retracted |
17.0/12.0 |
21.0/14.0 |
23.0/16.0 |
29.0/18.0 |
33.0/20.0 |
37.0/23.0 |
41.0/25.0 |
|
| MAB-3T
(m) |
| Extended/ |
23.0/13.5 |
27.0/15.0 |
31.0/16.5 |
35.0/17.5 |
39.0/19.0 |
43.0/20.5 |
|
| Retracted |
25.0/14.5 |
29.0/15.5 |
33.0/17.0 |
17.0/18.5 |
41.0/19.5 |
45.0/21.0 |
|
|
| Cabin
Dimensions |
| Internal Height |
3.0 m |
| Internal Width |
3.15 m |
|
| |
| Tunnel Dimensions |
| Internal Height |
2.18 m |
| Internal Width |
1.48 m |
|
| Weatherproof Door |
| Height |
3.00 m |
| Width |
1.775 m |
|
| Electrical Supply |
| Supply |
415v / 240v / 50 Hz |
| Lighting |
240 v / 50 Hz |
| Controls |
24v DC |
|
| Ambient Temperature |
Max +50ºc
Min -50ºc |
| Controlled Temperature |
|
| Relative Humidity [maximum] |
| External |
10% - 99% |
| Controlled |
55% |
|